Series-parallel Automatic Cage Tap Changer

  • Description
Product Detail

    Series-parallel Automatic Cage Tap Changer
    WSL Series off-circuit changer is used for oil-immersed transformer with no-load tap changer. It is usually of cage type structure. The switch transition type is variable with its inner structure. It has linear regulating, single-bridge stridden over connection, double-bridge stridden over connection, Y-- Delta transition, series--parallel connected transition, positive reverse regulation etc. This tap changer is classified into two types, one called tank head type, the other called bell covered type. The operation method can be classified into two types, one is handled on the tank head or to the grounding, and the other is driven with motor. They are used for power transformer, rectification transformer or furnace transformer in following specification range, rated frequency with 50Hz or 60Hz, rated voltage with 35kV, 66kV and110kV, rated current with 250A~2000A. This type of tap changer can only be operated in transformer under non-energized condition.

    Series-parallel automatic cage off load tap changer can be manufactured in special tap changer with large current, multiple taps, and relatively high voltage according to user requirements. A resistor that is used to limit the circulating current during transition only from one tap position to another. The transition resistor is only utilized in transition. The transition resistor is not designed to carry full load current. The Transition resistor is found only in a resistance type LTC. The transfer switch may also be referred to as the “Diverter Switch”. The transfer switch is used to interrupt the load so the selector switch can change position without arcing. The transfer switch contacts are made of an arc erosion resistant material called Elkonite (copper-tungsten) and is designed to arc (not heat) under normal conditions.

    Model Explanation
     WSL ?D? ?/?-???F/Y
        W:  off-circuit
        S :  three-phase
        L :  cage type
        ?:  voltage regulation model
        D:  automatic electric  
        ?:  L for vertical ; W for horizontal
        ?:  rated current
        ?:  rated voltage
        ?:  number of tapping heads
        ?:  number of tapping position
        F/Y: square flange or round flange

    Voltage Regulation Model
        I  :  linear regulating
        II :   central point
        III :  neutral point
        IV :  Y-? conversion
        V :   series-parallel connection
        VI :  positive and negative regulation           

    Samples Technical Data

    Model no.

    Voltage regulating

    part

    Installation dimension mm

    Power frequency withstand voltage

    (kv/1min)

    L1

    L2

    H1

    H

    Md

    To earth

    Inter phase

    Inter contact

    WSL?DL200~630/10-6×5~12×11 F

    Central point

    210

    110

    540

    720

    200A:Md=M12;400A:Md=M16;630A:Md=M18

    45

    45

    18

    WSL?DL200~630/10-5×5~12×12 F

    Neutral point

    210

    110

    540

    720

    WSL?DL800~1000/10-6×5~10×9 F

    Central point

    230

    130

    610

    790

    WSL?DL800~1000/10-5×5~10×10 F

    Neutral point

    230

    130

    610

    790

    WSL?DL200~630/35-6×5~10×9 F

    Central point

    275

    170

    710

    890

    100

    95

    30

    WSL?DL200~630/35-5×5~10×10 F

    Neutral point

    275

    170

    710

    890

    WSL?DL800~1000/35-6×5~10×9 F

    Central point

    300

    195

    810

    990

    WSL?DL800~1000/35-5×5~10×10 F

    Neutral point

    300

    195

    810

    990