Add to Favorites
Share

On-load Tap-changer

  • Description
Product Detail

    On-load Tap-Changer
     A tap-changer is a mechanism in transformers which allows for variable turn ratios to be selected in discrete steps. Transformers with this mechanism obtain this variable turn ratio by connecting to a number of access points known as taps along either the primary or secondary winding. These systems usually possess 33 taps (one at center "Rated" tap and sixteen to increase and decrease the turn ratio) and allow for ±10% variation (each step providing 0.625% variation) from the nominal transformer rating which, in turn, allows for stepped voltage regulation of the output.

    The uniformly designed transformer oil filter on load tap changer has got the advantages of advanced structure. Oil filter on load tap selector has reliable operation, long service life and convenient maintain etc. these transformer tap-changers are applying to such oil-immersed power transformer of 50Hz, under 35KV rated voltage and 400A rated current.

    Online oil filter function will extend the service life and maintenance time of tap changer.

    Liaoning Jinli Electric Power Electrical Appliance Co., Ltd was founded in 1986. It is one of the leading companies that specialized in producing transformer accessories, such as off circuit tap changer, on load tap changer, temperature controller, pressure release valve etc. It well sells at Chinese domestic and abroad market such as Australia?New Zealand?Canada?Indonesia Peru and so on.

    After more than 30 years development, the company has been strong in technical resource, and has accumulated rich experience of systematic design and practice and also established integrated product series.

    Model Explanation
     SY?Z(Z) - ?/?-?L
        S : three-phase
        Y : on load
        ?: voltage connection model
        Z : adopting resistance transit
        Z : direct switch
        ?: rated current
        ?: rated voltage
        ?: number of voltage regulation grades
        L : online oil filter

    Main Technical Data

    Application Scope

    Oil-immersed Distribution Transformer 

    Connection Model

    SYXZZ : three phase Y connection neutral point linear

    voltage regulation

    SYJZZ : three phase central point bridge voltage regulation

    SYTZZ : three phase any connection linear voltage regulation

    Three-phase Max. Rated Current  

    400A

    Max.Rated Voltage

    600V

    Max.Voltage of Device Um

    40.5KV

    Max.Tap Positions

    17 or others

    Connection Model Shows as Following 

    ?image002.png?image004.png?image006.png
    (Y connection neutral point)(Y connection neutral point with lead wire)(Y connection central bridge point) 
    ?image008.png?image010.png?image012.png
    (D connection central bridge point)(D connection terminal point)(Auto type terminal point)

    Sample Outline Dimension Diagram 

    image014.png    

    Sample Model Parameters

    Serial number

    Model No.

    (A)

    Rated

    current

    (v)

    Rated

    voltage

    Installation dimension(mm)

    H

    H1

    H2

    H3

    Md

    1

    SYXZZ 50/10 -3~5

    50

    10

    615

    305

    120

    60

    M8

    2

    SYXZZ 100/10-5~9

    100

    10

    682

    350

    125

    66

    M8

    3

    SYJZZ 100/10-5~7

    100

    10

    750

    440

    125

    100

    M8

    4

    SYJZZ 200/35-5~9

    200

    35

    1500

    190

    170

    715

    M12

    5

    SYJZZ 300/35-5~9

    300

    35

    1500

    190

    170

    715

    M14

    6

    SYJZZ 400/35-5~9

    400

    35

    1700

    220

    235

    910

    M16

Send your message to this supplier
To:  

Liaoning Jinli Electric Power Electrical Appliance Co.,Ltd

* Content:  

For better quotations, include:

- A self introduction

- Special requests, if any

Quantity:  

  
You May Like
Not exactly what you want? One request, multiple quotations Get Quotations Now >>
Related Searches :