On Load Tap-changer

  • Description
Product Detail

    On Load Tap-Changer
    Tap changers exist in two primary types, no load tap changers (NLTC) which must be de-energized before the turn ratio is adjusted and on load tap changers (OLTC) which may adjust their turn ratio during operation. The tap selection on any tap changer may be made via an automatic system, as is often the case for OLTC, or a manual tap changer, which is more common for NLTC. Additionally, tap changers are often placed on the high voltage (low current) transformer winding for easy access and to minimize the current load during operation.

    For many power transformer applications, a supply interruption during a tap change is unacceptable, and the transformer is often fitted with a more expensive and complex on load tap changing (OLTC, sometimes Load Tap Changer, LTC) mechanism. On load tap changers may be generally classified as either mechanical, electronically assisted, or fully electronic.

    An On load tap changer (OLTC), also known as under- load tap changer (ULTC). Tap changers typically use numerous tap selector switches which may not be switched under load, broken into even and odd banks, and switch between the banks with a heavy-duty diverter switch which can switch between them under load. The result operates like a dual-clutch transmission, with the tap selector switches taking the place of the gearbox and the diverter switch taking the place of the clutch.

    These transformer tap-changers are applying to such oil-immersed power transformer of 50Hz, under 35KV rated voltage and 400A rated current. Online oil filter function will extend the service life and maintenance time of tap changer.

    Model Explanation
     SY?Z(Z) - ?/?-?L
        S : three-phase
        Y : on load
        ?: voltage connection model
        Z : adopting resistance transit
        Z : direct switch
        ?: rated current
        ?: rated voltage
        ?: number of voltage regulation grades
        L : online oil filter

    Main Technical Data

    Application Scope

    Oil-immersed Distribution Transformer 

    Connection Model

    SYXZZ : three phase Y connection neutral point linear voltage regulation

    SYJZZ : three phase central point bridge voltage regulation

    SYTZZ : three phase any connection linear voltage regulation

    Three-phase Max. Rated Current  

    400A

    Max. Rated Voltage

    600V

    Max.Voltage of Device Um

    40.5KV

    Max.Tap Positions

    17 or others

    Connection Model Shows as Following 

    ?image002.png?image004.png?image006.png
    (Y connection neutral point)(Y connection neutral point with lead wire)(Y connection central bridge point)
    ?image008.png?image010.png?image012.png
    (D connection central bridge point)(D connection terminal point)(Auto type terminal point)

    Sample Outline Dimension Diagram 

    image014.png

    Sample Model Parameters

    Serial number

    Model No.

    (A)

    Rated

    current

    (v)

    Rated

    voltage

    Installation dimension(mm)

    H

    H1

    H2

    H3

    Md

    1

    SYXZZ 50/10 -3~5

    50

    10

    615

    305

    120

    60

    M8

    2

    SYXZZ 100/10-5~9

    100

    10

    682

    350

    125

    66

    M8

    3

    SYJZZ 100/10-5~7

    100

    10

    750

    440

    125

    100

    M8

    4

    SYJZZ 200/35-5~9

    200

    35

    1500

    190

    170

    715

    M12

    5

    SYJZZ 300/35-5~9

    300

    35

    1500

    190

    170

    715

    M14

    6

    SYJZZ 400/35-5~9

    400

    35

    1700

    220

    235

    910

    M16