Add to Favorites
Share

De-energized Tap Changer

  • Description
Product Detail

    De-energized Tap Changer

    This is a relatively recent development which uses thyristors both to switch the transformer winding taps and to pass the load current in the steady state. The disadvantage is that all non-conducting thyristors connected to the unselected taps still dissipate power due to their leakage currents and they have limited short circuit tolerance. This power consumption can add up to a few kilowatts which appears as heat and causes a reduction in overall efficiency of the transformer; however, it results in a more compact design that reduces the size and weight of the tap changer device. Solid state tap changers are typically employed only on smaller power transformers.

    A multiphase reactor-switching tap selector has a single geneva mechanism operating three shafts which traverse phase plates carrying all of the contacts and the vacuum switching cell and rapid release mechanism for each of the phases. The geneva mechanism operates the tap selection contacts directly through its shaft and is coupled to other shafts for operating the pre-selector contacts, the bypass contacts and the vacuum switching cells. All three shafts traverse all of the phase plates.

    Professional workmanship, plenty of know-how, the right dash of improvisation skills and lots of hands-on experience - just the right mix to make our service specialists are perfect for your tasks. Regular training up-grades and advanced training classes ensure our staff’s continuous high-level competence. The best guarantee for a professional and state-of-the-art maintenance performance. And our specialists’ know-how does not end at today´s Jinli tap-changer type series. They are just as competent when it comes to older type tap-changers,

    Model Explanation
     WSP ? - ?/?-???
        W:  off-circuit
        S :  three-phase or D for single phase
        P :  round type tap chager
        ?:  voltage regulation model
        ?:  rated current
        ?:  rated voltage
        ?:  number of tapping heads
        ?:  number of tapping position
     Voltage Regulation Model
        I  :  terminal point
        II :   central point
        III :  neutral point
        IV :  Y-? conversion

    Samples Technical Data

    Specifications

    WSP 63

    WSP 125

    WSP 250

    Phase number

    three-phases

    Connection mode

    Central point (?)  Neutral point (?) 

    Rated through current (A)

    63

    125

    250

    Short-circuit capacity

    Heat stableness current(KA/2s)

    1.6

    2.5

    3.75

    Dynamic stableness current(KA)

    4

    6.25

    9.375

    Rated frequency

    50~60

    Insulation level(KV)

    Rated Voltage

    10KV

    20KV

    35KV

    Power-frequency withstand Voltage(50Hz/1min)

    42KV

    55KV

    95KV

    Impulse(1.2/50µs)

    75KV

    125KV

    250KV

    Sealing Performance(KPa/24h)

    60

    Machine life(Thousands of times)

    2